Light Meter Calibration Constant
The update speed is how often a new measurement is displayed.
Light meter calibration constant. Ideally you want to use a lux meter to measure the amount of light hitting a workstation or similiar. Calibrate option if you have a calibrated light meter or known. The app will average the data over the time constant weighting it with a linear fall off over the length of the time constant. Two receptor types are common.
The light meter then gathers the reflected or incident light levels as per the type used. Light meter ap 881e light meter for plants illuminance meter lux meters with display 3999 range from 1 300 000lux unit lux fc max min back light data hold data storage by aoputtriver 32 99 32. Graph shows the time depedence of the light. Values for the reflected light calibration constant k vary slightly among manufacturers.
The time constant can be set to 0 5 seconds 1 second 2 seconds or 5 seconds. An incident meter should be pointed toward the camera a button is present on the side of the light meter. Iso 100 in the external exposure meter and the camera and make sure that all correction values are at 0. To calibrate your meter we recommend the following method.
Autoscale or manual pinch pan y axis. A value of 250 is commonly used. K is calibration constant per lambert s cosine law if we have a perfect diffuser then reflectance r is r pi l e pi k cwhere l is luminancee is illuminance k is the calibration constant for a reflected meter andc is calibration constant for an incident meter for an 18 gray card r 18. Firstly you need to hold the meter in front of the subject.
Using k 12 5 the relationship between ev at iso 100 and luminance l is then. The incident light calibration constant depends on the type of light receptor. Is is almost impossible to measure the amount of light given off by 1 light in the conditions you describe. Properly the meter calibration constant as well as the iso speed should be stated but this seldom is done.
Light meter calibration light meters are utilized in a variety of industries and applications including photography cinematography osha compliance security quality assurance photosensitive materials regulatory requirements process controls and clean room standards. A common choice is 12 5 canon nikon and sekonic. 4 time constant options. Flat cosine responding and hemispherical cardioid responding.
Set the same iso value e g. Switch the camera to manual mode and deactivate all functions that affect the exposure. In your example the second reading is higher because the light meter is picking up light from the other lights in the area. With a flat receptor iso 2720 1974 recommends a range for of 240 to 400 with illuminance in lux.
Calibrate a light meter.