Light Gage Metal Stud Shear Walls
Jay larson created date.
Light gage metal stud shear walls. Ii shear wall values for light weight steel framing preface this report presents the results of monotonic and cyclic tests of 42 full size cold formed steel framed shear walls sheathed with plywood oriented strand board osb and gypsum wallboard gwb. No longer just a division between space. Track thickness equal to or greater than the stud thickness both flanges of the stud attached to the track studs not adjacent to wall openings or discontinuities in the track. It is estimated that approximately 60 of the metal studs used in the united states are for interior non structural wall partitions.
L300 09 design of end posts for diaphragm shear walls s100 16 antiterrorism design requirements for cfs framing t001 09 fire and acoustic rated assemblies for multi. No longer just studs tracks and headers. The steelsmart structural design suite provides construction professionals with the structural design software tools engineered for both fast and accurate design and detailing of light steel framing lsf studs and connectors. Light steel framing design standards author.
The findings provided a basis for continued research and development efforts leading to. Double studs back to back were used at the ends of the walls. 2 1 2 250s 3 1 2 350s 3 5 8 362s 4 400s 5 1 2 550s 6 600s 8 800s 10. The wall stud web crippling calculations assume the following.
This eccentricity must be considered in design particularly in high seismic zones. Light gauge metal stud framing can be labor intensive in comparison to the low cost of the materials. Steelsmart structural design software suite for light steel framing. Clarkdietrich cold formed steel c studs general cold formed steel framing faqs general steel home construction faqs new clarkdietrich itools structural stud lookup tool clarkdietrich studs are made in a variety of flange widths to meet different applications.
Studs both static and cyclic load tests were conducted on walls with 3 1 2 x 1 5 8 studs spaced at 24 in. The design of walls is often complicated by the lack of analytical methods for the evaluation of the strength and rigidity. Wall stud design all steel design. Shear φ v 0 80 web.
Not only does light gauge metal framing offer durability strength and stability for wall partitions it is also. 3 0 shear wall tests 3 1 tests by serrette 1997 on walls with 3 1 2 x 1 5 8 in. Design by testing is a possibility if large numbers of identical walls are. Steel framing wall stud design aisi s211 07.
Steelsmart raises the bar for the design and analysis of cold formed steel cfs by seamlessly.